Nortel Networks DCT1900 User Manual
Page 127
Technical Product Manual - DCT1900
Configuration Directions, Base Station Powering
Config-DCT1900/R8/mw
4-7
© 2000-2005
Table 4–4 Power Consumption (Watts) of Base Stations and Cabling when Powered with 48V
26 AWG (0.4 mm) wire size (
∅)
24 AWG (0.5 mm) wire size (
∅)
22 AWG (0.64 mm) wire size (
∅)
Cable
length
(Feet)
1 pair
2 pairs
3 pairs
1 pair
2 pairs
3 pairs
1 pair
2 pairs
3 pairs
0
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
82
8.7
8.6
8.6
8.6
8.6
8.5
8.6
8.5
8.5
164
9.0
8.7
8.6
8.8
8.6
8.6
8.7
8.6
8.6
246
9.3
8.8
8.7
9.0
8.7
8.6
8.8
8.6
8.6
328
9.6
9.0
8.8
9.2
8.8
8.7
8.9
8.7
8.6
410
10.0
9.1
8.9
9.4
8.9
8.7
9.0
8.7
8.6
492
10.4
9.3
9.0
9.6
9.0
8.8
9.1
8.8
8.7
574
11.0
9.4
9.1
9.8
9.1
8.9
9.2
8.8
8.7
656
11.7
9.6
9.2
10.1
9.2
8.9
9.3
8.9
8.7
738
12.9
9.8
9.3
10.4
9.3
9.0
9.5
8.9
8.8
820
16.0
10.0
9.4
10.8
9.4
9.0
9.6
9.0
8.8
902
-
10.2
9.5
11.2
9.5
9.1
9.7
9.0
8.8
984
-
10.4
9.6
11.7
9.6
9.2
9.9
9.1
8.9
1066
-
10.7
9.7
12.4
9.7
9.2
10.1
9.1
8.9
1148
-
11.0
9.8
13.4
9.8
9.3
10.3
9.2
8.9
1230
-
11.3
10.0
16.0
10.0
9.4
10.5
9.3
9.0
1312
-
11.7
10.1
-
10.1
9.4
10.7
9.3
9.0
1476
-
12.9
10.4
-
10.4
9.6
11.2
9.5
9.1
1640
-
16.0
10.8
-
10.8
9.7
11.9
9.6
9.2
1804
-
-
11.2
-
11.2
9.9
12.8
9.7
9.2
1968
-
-
11.7
-
11.7
10.1
14.6
9.9
9.3
2132
-
-
12.4
-
12.4
10.3
-
10.1
9.4
2296
-
-
13.4
-
13.4
10.5
-
10.3
9.5
2460
-
-
16.0
-
16.0
10.8
-
10.5
9.6
2624
-
-
-
-
-
11.0
-
10.7
9.7
2788
-
-
-
-
-
11.4
-
10.9
9.8
2952
-
-
-
-
-
11.7
-
11.2
9.9
3116
-
-
-
-
-
12.2
-
11.5
10.0
3280
-
-
-
-
-
12.7
-
11.9
10.1
3608
-
-
-
-
-
14.6
-
12.8
10.4
3936
-
-
-
-
-
-
-
14.6
10.7
4264
-
-
-
-
-
-
-
-
11.0
4592
-
-
-
-
-
-
-
-
11.4
4920
-
-
-
-
-
-
-
-
11.9
5248
-
-
-
-
-
-
-
-
12.4
5576
-
-
-
-
-
-
-
-
13.2
5904
-
-
-
-
-
-
-
-
14.6