beautypg.com

Nortel Networks DCT1900 User Manual

Page 324

background image

Technical Product Manual - DCT1900

Installation Instructions, Modular Cabinet – Cables

26-20

Install-DCT1900/R8/mw

© 2000-2005

26.16 DTU/MDF Twisted Pair Cable – TSRNB 101 50 or AWS1034 (T1 - 100 ohm)

The DTU/MDF twisted pair cable AWS1034 (see Figure 26–19) consist of a 100 ohm shielded
cable terminated with two connectors. The cable is used to connect a DTU to a MS or PBX via a
MDF (Main Distribution Frame). The shielding of the cables is connected to the cabinet via a
clamp which also functions as a strain relief. The length of the cable is 16 ft. Excess cable length
may be trimmed at installation.

The TSRNB 101 50 cable is terminated at one end in 2 RJ45 connectors. These should be cut off
to allow for punch down.

WHT

WHT

WHT

BRN

GRN

1 2

7

8

WHT

WHT

ORN

BLU

1 2

7

8

WHT

WHT

WHT

ORN

BLU

1 2

7

8

X2

X1

RCV
pairs

XMIT
pairs

View looking into DTU board edge

X1

X2

White/Blue pair

White/Orange pair

White/Green pair

White/Brown pair

Shield clamp

(K1)

(K2)

(1034 cable)


Fig. 26–19 DTU Twisted Pair Cable - T1