beautypg.com

7 adding boards, 8 fuses, Switch off modular cabinet – Nortel Networks DCT1900 User Manual

Page 380: Remove the power cable connected to pw-ext

background image

Technical Product Manual - DCT1900

Maintenance, Part Replacement

5-4

Maint-DCT1900/R8/mw

© 2000-2005

-

Execute Add command for the New Base Stations in the Base Stations window.

z

SLU boards:
-

Execute Replace command for the CLU. Remove and re-insert into new position.

-

Refresh Radio Exchange and Base Station windows.

-

Execute Remove command for the old CLU position.

-

Execute Add command for the New Base Stations in the Base Stations window.

5.7

Adding Boards

New boards placed into the system are automatically detected by the CPU within 1 minute.

5.8

Fuses

In a Modular Cabinet system, the following replaceable fuses are found:

Modular Cabinet – Fuses near power switch
Left fuse, in + rail, red wire:

z

Protection against overload AC.

z

Protection against overload DC supply (non–earthed).

z

Protection against reversed DC supply (non–earthed) connection.

z

Protection against reversed PBX (–48V) connection.

z

Protection against DC supply with grounded – rail.

Right fuse, In – rail, black wire.

z

Protection against overload PBX supply with grounded + rail (–48V).

z

Protection against overload AC.

z

Protection against overload DC supplies (non–earthed).

z

Protection against reversed DC supply (non–earthed) connection.

Replacement:
1.

Switch off Modular Cabinet.

2.

Replace fuse.

3.

Switch on Modular Cabinet.

Modular Cabinet – Fuse near power switch to Backplane

z

Protects backplane.

Modular Cabinet – Fuses on the MCCB in Modular Cabinet
The fuses on the MCCB are only used for the "external power" connection.

Front fuse:

z

Protection against overload in Base Station powering via PW3/4/5/6.

Rear fuse:

z

Protection against overload in Base Station powering via PW1/2/7.

Replacement:
1.

Remove the power cable connected to PW–EXT.

2.

Replace the fuse.

3.

Re–connect the power cable.