4–14

Option 25 — Binary Count Slew

MVP/L150

Option

Number

Display

Configuration
Description

.0

25.0

With Control Code 10H (binary count of 0) causes one line slew,
11H (binary count of 1) causes a two line slew, and each code incre-
ments by one up to Control Code 1FH (binary count of 15) which
causes a 16 line slew.

.1

25.1

With set, the entire sequence is shifted by one so that Control Code
10H (binary count of 0) causes a 16 line slew instead of one, 11H
causes a one line slew, and Control Code 1FH (binary count of 15)
causes a 15 line slew.

NOTE: If Paper Instruction (PI) is enabled by configuration option 61.1,

option 25 enables the user to shift the values for the line slew

control codes by one. Note that a single PI (hex 00) command will

slew a blank line.

150B/L150B

Option

Number

Display

Configuration
Description

.0

25.0

Slew 1 to 16 lines for line terminators PI (hex 00) thru PI (hex 0F).

.1

25.1

Slew 1 to 15 lines for line terminators PI (hex 00) thru PI (hex 0F).
PI (hex 00) and PI (hex 01).

NOTE: Note that a single PI (hex00) command will slew a blank line. The

distance between each P–Series plot dot row will be wrong if ESC

or SOH ’3’n or ’A’n is active. However, single PI (hex 00 – hex 0F

or EVFU slew commands will slew lines with vertical line spacing

set with ESC or S0H ’3’n or ’A’n commands. In addition to the

ESC and S0H start header characters, the ETX character is also

allowed (Hex 03).