beautypg.com

Self–tests – Printronix MVP Series User Manual

Page 217

background image

Routine Service and Diagnostics

9–10

Self–Tests

There are twenty printer self–tests you can use to determine configuration,

evaluate print quality, and check paper motion. Self–tests are divided into six

general types: Configuration, Automatic Sequence, Repeating, Print, Paper

Motion and Hex Dump. A detailed explanation of the six types of self–tests

and the procedures to initiate a test are contained in the following

paragraphs. All tests are listed in Table 9–2. Always use full size computer

paper in the printer when running any of the self–tests.

Self–Test Procedure

1.

Lift the printer cover. Make sure the RDY indicator is flashing.

NOTE: Always use full size computer paper when running the self–tests or

else you may harm the platen.

2.

Press and release the 2nd FUNC switch.

3.

Press and release the ADDR switch; the switch indicator will stay on

steadily. The digital panel will display two digits: the last code used or

“00.0”.

4.

Select a self–test from Table 9–2.

5.

Press and release the ADDR switch until the digital panel displays the

first two digits of the test selected. (If pass the number, press and hold

the ADDR switch. The digits will advance to 99, then begin at 00 or

refer to the configuration chapter for an alternative method that reverses

the count direction.)

6.

Press and release the DATA switch (advances .1 each time) until the

desired third digit (decimal) is displayed.

7.

Press and release 2nd FUNC switch to start printing.

8.

Press and release RDY switch to stop printing.

NOTE: If the RDY indicator flashes at the end of the test, the test was

successfully completed.