Preliminary testing – Printronix MVP Series User Manual
Page 34
Installation
2–12
Applying Power
After you properly install the printer, apply power by performing the
following steps.
1.
Check that the voltage shown on the printer identification label (located
at the right rear of the printer) is the same as your power source. Voltage
in North America is usually 120 volts/60 Hz, and printers sold in the
United States are configured for power in that range. If your printer
label reads V120 VAC and your power source is also 120 volts, plug the
female end of the power cord into the male connector on the right rear
of the printer. Plug the male end into the wall outlet.
WARNING
Operator hazard and printer damage is possible if the printer is
connected to an incorrect power source.
2.
Press the ON/OFF switch to ON. When you press the power switch to
On, all indicators will light for approximately two seconds, and the
RDY indicator remains lit to show the printer is on–line.
NOTE: The power On–Off switch is located at the rear of the printer and is
marked “O” for power off, and “I” for power on.
3.
After loading the ribbon and paper, conduct a self–test as described in
the Routine Service and Diagnostics chapter.
Preliminary Testing
After you install and apply power to the printer, it is ready for preliminary
testing. Refer to the “Self Tests” section in the Routine Service and
Diagnostics chapter for the self–test instructions that apply to your specific
type of MVP printer. Once the self–test has been completed, examine the
print quality. The characters should be fully formed and of uniform density.
If the test does not run or characters appear malformed, contact your
authorized service representative.