Printronix MVP Series User Manual
Page 115
EVFU
6–3
Channel Assignment
All data bytes received after the Start Load code are interpreted as channel
assignment data until the End Load code is received.
A maximum of 12 channels can be assigned to one physical line on the form.
Two eight–bit data bytes (EVFU characters) are required per line. As show in
Figure 6–1, the least significant 6 bits of the first data byte are used to assign
channels 1 through 6; the least significant 6 bits of the second data byte are
used to assign channels 7 through 12. If a bit is set, the corresponding
channel is assigned. If a bit is not set, the channel is not assigned.
For example, assume 01 (hex) and 00 (hex) are the first two data bytes sent
following the Start Load code:
01 hex = 0000 0001
00 hex = 0000 0000
NOTE: This sequence results in Channel 1 being assigned to line 1 of the
form. No other channels are assigned to Line 1.
Use the following guidelines when assigning channels:
•
Channel 1 TOF must be entered before any other channel data to assign
Line 2 as the TOF. Sending channel data before assigning Channel 1 as
the TOF will cause the loading sequence to be invalid and an EVFU
memory reset.
•
The last channel loaded is assigned to the bottom–of–form.
•
Each line on the form requires two bytes. For blank lines, the two bytes
should not contain channel assignments. That is, the data bytes sent in
the load program corresponding to a blank line on the form should not
set any of bits 1 through 6.
You can assign channels up to 143 lines (285 EVFU bytes). The EVFU
ignores anything more than 286 bytes until the End Load code is received; if
572 bytes are received without an End Load code, the End Load code is
forced and the load routine is terminated.