EVFU

6–3

Channel Assignment

All data bytes received after the Start Load code are interpreted as channel

assignment data until the End Load code is received.

A maximum of 12 channels can be assigned to one physical line on the form.

Two eight–bit data bytes (EVFU characters) are required per line. As show in

Figure 6–1, the least significant 6 bits of the first data byte are used to assign

channels 1 through 6; the least significant 6 bits of the second data byte are

used to assign channels 7 through 12. If a bit is set, the corresponding

channel is assigned. If a bit is not set, the channel is not assigned.

For example, assume 01 (hex) and 00 (hex) are the first two data bytes sent

following the Start Load code:

01 hex = 0000 0001

00 hex = 0000 0000

NOTE: This sequence results in Channel 1 being assigned to line 1 of the

form. No other channels are assigned to Line 1.

Use the following guidelines when assigning channels:

Channel 1 TOF must be entered before any other channel data to assign

Line 2 as the TOF. Sending channel data before assigning Channel 1 as

the TOF will cause the loading sequence to be invalid and an EVFU

memory reset.

The last channel loaded is assigned to the bottom–of–form.

Each line on the form requires two bytes. For blank lines, the two bytes

should not contain channel assignments. That is, the data bytes sent in

the load program corresponding to a blank line on the form should not

set any of bits 1 through 6.

You can assign channels up to 143 lines (285 EVFU bytes). The EVFU

ignores anything more than 286 bytes until the End Load code is received; if

572 bytes are received without an End Load code, the End Load code is

forced and the load routine is terminated.