Interfaces

8–2

Introduction

The MVP–Series printer interfaces are logically and electronically

compatible with the Centronics and Dataproducts interfaces. The Centronics

and Dataproducts interfaces allow the parallel transfer of 8 data bits, one byte

at a time. The switch from one interface to the other requires a simple change

of the printer’s input/output (I/O) cable, terminating resistors, and

Configuration Option 66 (see “Switching Interfaces” on page 8–26 ).

Centronics and Dataproducts Interface Characteristics

Centronics and Dataproducts interface circuit characteristics are as follows.

Interface Cable

The cable must not exceed 40 feet and must allow the transmission of signals

having standard TTL logic level (0.0V to +0.5V low and +2.4V to +5.25V

high). Use shielded cable with the shield grounded to minimize electrical

noise.

Logic Levels

0.0V to +0.5V low; +2.4V to +5.25V high.

Receivers

TTL 74LS14 with a 1000–ohm pull–up terminating resistor pack in location

18C (Centronics) or optional 220–ohm and 330–ohm pull–up/pull–down

terminating resistor packs in locations 18C and 17C, respectively

(Dataproducts).

Drivers

TTL 7407 with a 1000–ohm pull–up terminating resistor pack in location

15C (Centronics or Dataproducts).

Terminating Resistors

The Centronics parallel interface requires that 1000–ohm resistor packs be

installed at Parallel Controller PCBA coordinates 15C and 18C see

Figure 8–5. Typical circuits using the resistors are shown in Figure 8–6. The

Dataproducts Interface requires the 220–ohm resistor pak at coordinates 18C

and a 300–ohm pack at coordinates 17C. A 1000–ohm pack is installed at

location 15C. A resistor pack is not required with the Serial Controller

PCBA.

Logic Configuration