Interfaces

8–26

Switching Interfaces

As previously mentioned, switching from one interface to the other requires a

simple change of the printer’s input/output (I/O) cable, terminating resistors,

and Configuration Option 66 (refer to Switching Interfaces in this chapter).

Interface Cables

The Centronics or Dataproducts interface cable must not exceed 40 feet in

length and must allow the transmission of signals having standard TTL logic

levels (0.0V to +0.5 low and +2.4V to +5.25V high). For minimum electrical

noise, use shielded cable and ground the shield.

Terminating Resistors

The Centronics parallel interface requires that 1000–ohm resistor packs be

installed at Parallel Controller PCBA coordinates 15 C and 18C as shown in

Figure 8–5. Typical circuits using the resistors are shown in Figure 8–6.

The Dataproducts interface requires the 220–ohm resistor pack at coordinates

18C and a 330–ohm pack at coordinates 17C. A 1000–ohm pack is installed

at location 15C.