2–3
Installation
Power Requirements
CAUTION
MVP–Series printers employ a single phase, capacitive start shuttle
motor. All models require 120 volts at 4 amps for a duration of 0.5
seconds at motor start–up. This is an important power requirement and
is recommended to supply power from a separate AC circuit of 20 amps
at 60 Hz.
VORSICHT
Die MVP Drucker benuetzen einen ein–phasigen, kapazitive–startenden
Pendelmotor. Die MVP Modelle benoetigen beim Anlassen 0,5 Sek. lang
25,4 A. Diese Stromanforderung ist wichtig und es wird empfohlen den
Strom aus einem gesonderten AC–Stromanschluss von 20 A bei 60 Hz zu
decken.
A label on the back of the printer near the power cord shows the voltage and
frequency requirements. The printer must be connected to the specified
power source, either 110, 220 or 240 volts at 50 to 60 Hz. Line voltage can
vary by 10%. The printer automatically senses and adjusts itself to conform
to the proper voltage. The printer contains primary circuit protection. Consult
an electrician if printer operation affects local electrical lines.