Configuration

4–8

Option 20 — Host Mode Control Programming Standard

Discussion

Option 20.0 is used to store data that allows you to select the Host Mode

Control. Option 20.1 allows up to 11 beginning characters (or headers) of

control code sequences that are valid when encountered in the data stream;

option 20.2 allows only one.

MVP/L150

Option

Number

Display

Configuration
Description

.0

20.0

Host Mode Control disabled (default)

.1

20.1

P–Series programming standard. (Control Code sequence for more
changes appearing in data stream are edited per conditions attached
to Configuration options 31 through 41.)

.2

20.2

ANSI programming standard. Control Code sequence for mode
change must begin with ESC (1BH).