Advanced Configuration Features
158
890USE17700 April 2004
Result of a Reflex
Block
Depending on the type of reflex block that you use, it will output either a Boolean or
a word as its result. Generally, the result is mapped to an action module, as shown
in the following table:
The result from a block is usually mapped to an individual channel on an output
module. Depending on the type of result that the block produces, this action module
may be an analog channel or a digital channel.
When the result is mapped to a digital or analog output channel, that channel
becomes dedicated to the reflex action and can no longer use data from the fieldbus
master to update its field device.
The exception is when a reflex block is the first of two actions in a nested reflex
action.
Reflex Action
Result
Action Module Type
Boolean logic
Boolean value
digital output
integer compare
Boolean value
digital output
counter
16-bit word
first block in a nested reflex action
timer
Boolean value
digital output
digital latch
Boolean value
digital output
analog latch
16-bit word
analog output