beautypg.com

Siemens SIMATIC PANEL PC 877 User Manual

Page 34

background image

Application planning

4.5 Mounting cut-out

SIMATIC Panel PC 877

4-10

Operating instructions, Release 07/2006, A5E00877780-01

Table 4-1

Dimensions for the mounting cut-out in mm

Control unit

L1

L2

L3

1)

L4

1)

L5

L6

2)

L7

2)

L8

2)

L9

2)

A1

A2

S1

S2

S3

S4

S5

3)

S6

3)

S7

3)

Tolerance

+1

+1

±0.2 ±0.5 ±0.5 ±0.5 ±0.5

+1

±1

±1

±1

±1

±1

±1

Key panel
12" TFT

15" TFT

450

450

290

321

465

465

235

279

112

112

186

135

25

165

16

16

10

17

78

51

78

51

56

56

Touch panel
15" TFT

19" TFT

450

450

290

380

465

465

235

235

112

112

16

16

10

10

81

46

81

46

56

33

1)

M6 thread or drilled holes of 7 mm diameter

2)

Cut-outs for the slots or inserted labels are required for 15'' key panels only

3)

Two clamps are required vertically for clamp mounting for the 19' touch panels only

Preparing the mounting cut-out

Steps for preparing the mounting cut-out
1 Select a location suitable for mounting, taking into account the mounting position.
2 On the basis of the dimension diagrams, check whether the required screw and pressure points

on the rear and the seal area are easily accessible after the completion of the mounting cut-out.

Otherwise the mounting cut-out is useless.

3 Complete the mounting cut-out in accordance with the dimensions.