beautypg.com

Siemens SIMATIC PANEL PC 877 User Manual

Page 120

background image

Maintenance and service

12.3 Separating the control unit from the computer unit

SIMATIC Panel PC 877

12-6

Operating instructions, Release 07/2006, A5E00877780-01

Separating the device in an uninstalled state

As an alternative, dismount the device completely and separate the control unit and

computer unit from one another in an uninstalled state. So that the processing unit, which is

swung away from the control unit, does not bend the lugs (4), place a surface under the

processing unit.

Mounting operator control unit on computer unit

To mount the operator control unit on the computer unit, perform the steps in reverse:

Caution
When you swing the control unit and processing unit together, make sure that the flatband

cables are correctly folded together and do not get squished.
In order to do this, fold the flatband cables gently with specific spacing, as shown. The bend

dimensions are specified in the following table. The USB cable does not have to be folded

because it is stored as a loop in the processing unit.

Figure 12-3 Separate the control unit from the computer unit, example regarding folding cables

Position

Bend dimension

A

4.5 cm

B

4 cm