Siemens SIMATIC PANEL PC 877 User Manual
Page 209
Detailed descriptions
17.1 Motherboard
SIMATIC Panel PC 877
Operating instructions, Release 07/2006, A5E00877780-01
17-17
Assignment of the display to the display select pins
The display select inputs are used to configure one of 15 possible displays automatically.
The display select inputs are equipped with pull-up resistors, i.e., these inputs have a high
signal if they are not connected. The input must be connected to GND if a low signal is to be
generated.
Pin No. LCD_SEL3
LCD_SEL2
LCD_SEL1
LCD_SEL0
Display type
0
low
low
low
low
reserved
1
low
low
low
high
1280x1024 (SXGA), TFT, 2
x 18-bit, LVDS channel 1
and 2
2
low
low
high
low
DVI LCD 640 x 480
3
low
low
high
high
DVI LCD 800 x 600
4
low
high
low
low
640 x 480 (VGA), TFT, 18
bits, LVDS channel 1
5
low
high
low
high
reserved
6
low
high
high
low
1024 x 768 (XGA), TFT, 18
bits, LVDS channel 1
7
low
high
high
high
800 x 600 (SVGA), TFT, 18
bits, LVDS channel 1
8
high
low
low
low
reserved
9
high
low
low
high
reserved
10
high
low
high
low
reserved
11
high
low
high
high
reserved
12
high
high
low
low
Reserved 1024 x 768
(XGA), TFT, 2 x 18-bit,
LVDS channel 1 and 2
13
high
high
low
high
DVI LCD 1024 x 768
14
high
high
high
low
DVI LCD 1280 x 1024
15
high
high
high
high
No LVDS display or DVI
LCD with automatic DDC ID