Detailed descriptions

17.1 Motherboard

SIMATIC Panel PC 877

17-8

Operating instructions, Release 07/2006, A5E00877780-01

LPT1 parallel interface, X134

The parallel interface (LPT 1) has the following pinout:

Parallel interface LPT1

PinNo. Abbreviation

Meaning

Input/Output

1

/ Strobe (CLK)

Data message

Output (open collector)

2

Data - Bit 0

Data channel 0

Output (TTL level)

3

Data - Bit 1

Data channel 1

Output (TTL level)

4

Data - Bit 2

Data channel 2

Output (TTL level)

5

Data - Bit 3

Data channel 3

Output (TTL level)

6

Data - Bit 4

Data channel 4

Output (TTL level)

7

Data - Bit 5

Data channel 5

Output (TTL level)

8

Data - Bit 6

Data channel 6

Output (TTL level)

9

Data - Bit 7

Data channel 7

Output (TTL level)

10

/ACK

Data acknowledge

Input (4.7 kO pull-up)

11

BUSY

Not ready

Input (4.7 kO pull-up)

12

PE (PAPER END)

Paper end

Input (4.7 kO pull-up)

13

SELECT

Device selection

Input (4.7 kO pull-up)

14

/ AUTO FEED

Automatically new line

Output (open collector)

15

/ ERROR

Device error

Input (4.7 kO pull-up)

16

/ INIT

Reset / Initialization

Output (open collector)

17

/ SELECT IN

Printer selection

Output (open collector)

18 – 25 GND

Ground