Troubleshooting/FAQs

14.2 Problems when Using Modules of Third-party Manufacturers

SIMATIC Panel PC 877

14-2

Operating instructions, Release 07/2006, A5E00877780-01

14.2

14.2

Problems when Using Modules of Third-party Manufacturers

Problem

Possible causes

To correct or avoid error
Check your computer configuration:

If the computer configuration corresponds with factory state,

please contact your technical support team.

If the computer configuration has changed, restore the

original factory settings. Remove all third-party modules,

then restart the PC. If the error no longer occurs, the third-

party module was the cause of the fault. Replace this

module with a Siemens module or contact the module

supplier.

Force a “Reset Configuration” using the BIOS setup.

I/O addresses are assigned

twice.

Hardware interrupts and/or DMA

channels are assigned twice.

Signal frequencies or signal

levels are incorrect.

Connector assignments deviate.

“Reset Configuration” in BIOS

SETUP has not been carried

out.

If the PC still crashes, contact your technical support team.

The PC crashes

during startup

If the performance of the

external 24 V power supply is

insufficient

use a larger power supply.