beautypg.com

Siemens SIMATIC PANEL PC 877 User Manual

Page 199

background image

Detailed descriptions

17.1 Motherboard

SIMATIC Panel PC 877
Operating instructions, Release 07/2006, A5E00877780-01

17-7

COM 2 serial interface (V24/Mouse), X31

The serial interface (COM 2) has the following pinout:

COM 2 serial interface (V24/Mouse)

PinNo.

Abbreviation

Meaning

Input/Output

1

DCD (M5)

Receiving signal level carrier

Input

2

RxD (D2)

Received data

Input

3

TxD (D1)

Transmitted data

Output

4

DTR (S1)

Data terminal ready

Output

5

GND (E2)

System ground (reference potential)

6

DSR (M1)

Ready for operation

Input

7

RTS (S2)

Request to send

Output

8

CTS (M2)

Clear to send

Input

9

RI (M3)

Incoming call

Input