beautypg.com

Siemens SIMATIC PANEL PC 877 User Manual

Page 217

background image

Detailed descriptions

17.2 Bus board

SIMATIC Panel PC 877
Operating instructions, Release 07/2006, A5E00877780-01

17-25

17.2.2

Assignment of the PCI IRQ channels to the PCI slots

Assignment of the PCI IRQ channels to the PCI slots

Box PC 840 V2

PCI modules interrupt assignment (PCI IRQ) in:

Module interrupt (Pin

No.)

Slot 1

Slot 2

Slot 3

Slot 4

INT – A (A6)

channel 1

channel 2

channel 3

channel 4

INT – B (B7)

channel 2

channel 3

channel 4

channel 1

INT – C (A7)

channel 3

channel 4

channel 1

channel 2

INT – D (B8)

channel 4

channel 1

channel 2

channel 3

Highlighted entries refer to master interrupts of the slot module