Siemens SIMATIC PANEL PC 877 User Manual
Page 162
Alarm, error and system messages
13.1 Boot error messages
SIMATIC Panel PC 877
13-2
Operating instructions, Release 07/2006, A5E00877780-01
On-screen error message
Meaning / suggestions
Keyboard error
Check whether the keyboard is properly connected.
Key seizure
Check whether a key on the keyboard has seized.
System RAM Failed at offset:
Memory error.
Contact your technical support team.
Shadow RAM Failed at offset:
Memory error.
Contact your technical support team.
Extended RAM Failed at offset: Memory error.
Contact your technical support team.
Failing Bits:
Memory error.
Contact your technical support team.
Operating system not found
Possible causes:
•
No operating system present
•
Wrong drive addressed (disk in drive A/B)
•
Incorrect active boot partition
•
Wrong boot drive settings in SETUP
•
Hard disk is not connected / defective
Previous boot incomplete
Default configuration used
Abort of the previous BOOT procedure, for example, due to a
power failure. Adjust the settings in SETUP.
System cache error Cache
disabled
Error in the CPU’s cache module.
Contact your technical support team.
Monitor type does not match
CMOS Run SETUP
The monitor does not match the SETUP entries.
Adapt the SETUP entries to the monitor.
System time-out
Hardware error.
Contact your technical support team.
Real-time clock error
Clock chip error.
Contact your technical support team.
Keyboard controller error
Keyboard error.
Contact your technical support team.