Replacing the instrument in its housing – Pyromation Series 610 1_16 DIN User Manual
Page 24

1
/
4
-DIN,
1
/
8
-DIN &
1
/
16
- DIN Controllers & Indicators - Product Manual
Replacing the Instrument in its Housing
With the required option modules correctly located into their respective positions the
instrument can be replaced into its housing as follows:
1. If required, move the CPU and PSU boards back together, taking care to locate the option
module tongues into the slots in the board opposite. Hold the main boards together whilst
relocating them back into the mounting struts on the front panel.
2. Align the CPU and PSU PCBs with their guides and connectors in the housing.
3. Slowly and firmly, push the instrument in position.
CAUTION:
Ensure that the instrument is correctly orientated. A mechanical stop will operate if
an attempt is made to insert the instrument in the wrong orientation, this stop MUST
NOT be over-ridden.
59305, Issue 6 – March 2006
Plug-in Options
Page 19