beautypg.com

Pyromation Series 610 1_16 DIN User Manual

Page 105

background image

1

/

4

-DIN,

1

/

8

-DIN &

1

/

16

- DIN Controllers & Indicators - Product Manual

Parameter

Legend

for 1 sec

followed

by

Set

Value

Adjustment Range &

Description

Default
Value

When
Visible

Units

Display

(

1

/

8

Din

Only)

'3

L type: 0 to 762 ºC

'"

L type: 32 to 1403 ºF

'

.

3

L type: 0.0 to 537.7 ºC
with decimal point

'

.

"

L type: 32.0 to 999.9 ºF
with decimal point

(3

N type: 0 to 1399 ºC

("

N type: 32 to 2551 ºF

+3

R type: 0 to 1759 ºC

+"

R type: 32 to 3198 ºF

-3

S type: 0 to 1762 ºC

-"

S type: 32 to 3204 ºF

/3

T type: -240 to 400 ºC

/"

T type: -400 to 752 ºF

/

.

3

T type: -128.8 to 400.0 ºC with
decimal point

/

.

"

T type: -199.9 to 752.0 ºF
with decimal point

)3

PtRh20% vs PtRh40%:
0 to 1850 ºC

)"

PtRh20% vs PtRh40%:
32 to 3362 ºF

).3

Pt100: -199 to 800 ºC

)/"

Pt100: -328 to 1472 ºF

)/

.

3

Pt100: -128.8 to 537.7 ºC
with decimal point

)/

.

"

Pt100: -199.9 to 999.9 ºF
with decimal point

:

0 to 20mA DC

:

4 to 20mA DC

:

0 to 50mV DC

.

10 to 50mV DC

:

0 to 5V DC

:

1 to 5V DC

:

0 to 10V DC

Input type and
Range
(Continued)

:

2 to 10V DC

63

for
Europe

6"

for
USA

Always

+


Page 100

P6010 & P8010 Model Group

59305, Issue 6 – March 2006

This manual is related to the following products: