Solare Datensysteme Solar-Log User Manual
Page 97

97
Configuring connected devices
18�5�4 Configuring EGO Smart Heaters
EGO Smart Heaters can be selected from the drop-down menu from the Device Configuration menu and
configured accordingly.
Procedure:
•
Select the Smart Heater from the drop-down menu under devices.
•
Enter the maximum storage temperature [C°].
The maximum storage temperature can range from 40°C to 80°C . When 0 is entered, the settings
from the Smart Heater for its potentiometer are used.
•
Select the operating mode from the meter configuration menu. The EGO Smart Heater can be con-
figured as a consumption meter or a sub-consumer.
•
Enter the maximum AC power and a name under Module Field, Power and Name.
•
SAVE
the settings.
Information on the maximum storage temperature for the EGO Smart Heater
By default, the maximum boiler temperature is adjusted with the rotary switch on the EGO Smart Heater.
To be able to control the temperature from the Solar-Log™, the rotary switch on the EGO Smart Heater has
to be set higher than the value from the Solar-Log™ because the settings from the rotary switch determine
the maximum temperature for external control
Example:
If the rotary switch is set to 40°C and the Solar-Log™ to 60°C, the settings from the Solar-Log™ will be
ignored and the value from the rotary switch will be applied. The range for the rotary switch has to be set
higher so that the Solar-Log™ can assume control. In the example to 60°C.
For this reason, we recommend setting the rotary switch to a maximum of 80°C – or the maximum broiler
temperature that is not to be exceeded – when the Solar-Log™ is to control the temperature externally.
The Solar-Log™ can control the temperature when it is in the range below the set maximum value.