Direct Device Configurations (Solar-Log 1000)
These check boxes are used to activate the display on the corresponding interface, and appear in
the various dialog boxes that appear one after the other in the dialog sequence.
•
Each interface can be selected by marking it and saving
•
On the right of the interface name, the display field indicates if and how the interface has already
been assigned. It also displays the inverter manufacturer and the baud rate used.
•
Select the large external display manufacturer used
•
If plant groups have been defined, you can select here which plant group is shown on the large
external display. If no groups are used, the whole plant is shown.
Note
If the display is being configured on the S0 output, a pulse factor has to be entered.
The pulse factor in Solar-Log 1000 must be the same as the pulse factor on the large
display.
26�11 Configuring alarm messages and signals for the alarm contact
The Solar-Log 1000 continuously monitors its internal alarm contact. If this contact is opened, it sets off an
alarm which can be indicated in various ways.
Note
Only set the alarm contact to active if you have connected an alarm circuit to the alarm
contact connection (a circuit between both pins of the alarm contact).
How to configure alarm signals and messages for the alarm contact:
•
Select the Config./Advance/Alarm Contact menu
The dialog for alarm contact settings is displayed.
•
Configuring the alarm messages for the alarm is triggered
Alarms can be communicated by E-mail, Relay, the Error-LED on the front panel, text message
(SMS) and/or through the internal Speaker of Solar-Log 1000. The e-mail, SMS and relay settings
must be already configured.
•
Enable the desired options (see above list).
•
If required, the alarm can be tested. Touch Test for 10 seconds
•
Touch Save