Connecting accessories
Connection through S0 output
If the S0 output is used, only the current feed-in power can be transmitted in the form of a pulse sequence.
The display has to calculate the power output and total yield by itself.
Wiring for a contact-controlled S0 output
Example: RiCo Electronic
The wiring consists of a 2-pin shielded cable (2x0.6 mm)
(max. length 100 m) and terminal block connector.
RiCo Large displays
RS485 Solar-Log™
Display
PIN
Assignment
5
S0-
6
S0+
Further information about the connection can be obtained from the manufacturer of the display.
Pulse factor
In the standard setting, Solar-Log™ sends 1000 pulses/kWh over the S0 output. The pulse factor must be
configured according to the size of the plant (kWp) in the
Configuration | Devices | Definition | External
Display
menu.
Pulse factor / plant size
Plant size kWp
Pulse factor
30 kWp
2000
60 kWp
1000
100 kWp
600
150 kWp
400
300 kWp
200
600 kWp
100
Note