Solare Datensysteme Solar-Log User Manual
Page 174

174
Direct Device Configurations (Solar-Log 1000)
26�4�2 Inverter selection
In the inverter selection, manufacturers of the inverters connected to Solar-Log 1000 can be selected and
assigned to all interfaces through a series of dialog boxes.
Inverter selection order:
•
RS485-A
•
RS485/422-B
•
CAN
•
Network
•
S0
The inverter selection dialog boxes are structured differently depending on the interface.
Procedure
•
Connect the device with the interface.
And then select the buttons.
•
A selection list of devices is displayed:
•
Select a connected device and touch
Select
to continue.
•
If no interface is assigned, select None.
•
After each switch selection, touch
Save
and then
Next
to go to the next dialog.
•
Set up each of the connected devices for all of the interfaces.
•
For the power meter on the SO input, select
Yes
or
No
.
Yes (= activate input) or No (= deactivate input)
•
When all of the devices have been properly defined, touch
Continue to Inverter Detection
or
•
If inverter detection is to be performed at a later time using the Inverter detection menu item, the
settings made up to this point can be saved: Touch
Save
.
26�4�3 Perform inverter detection�
The inverter detection function is used to find all of the inverters connected to the Solar-Log 1000 and
assigns them an address number. The inverter detection is based on the defined connected devices from
the initial configuration.
The number and types of devices are automatically detected here.
If the number of inverters changes, the internal database needs to be restructured, and this can be a
lengthy process depending on the amount of data already stored.
The
Inverter Detection
menu is automatically started once the initial setup and configuration have been
completed. However, it can separately at any time.