Special functions
•
Automatic timer
The automatic time profile operators independent of the current PV production. Up to 10 periods can
be defined based on the time.
•
Performance Visualization
The performance visualization profile can be used in connection with the Solar-Log™ Smart Relay Box.
The Relay Box has 8 relays. The relays can be switched on in stages. The value for the activation the
individual relays needs to be defined.
•
Threshold and Time Control
With this profile, appliances can be controlled based on the configured switching thresholds and also
with optional automatic timer settings. An upper threshold for activation and a lower threshold for
deactivation need to be configured. Additionally, a time period can be defined in which the appliance
is switched on or off if this has not already been done via the threshold control. The minimum duration
the appliance has to be switched on for is defined in the previous duration box. If this duration is not
covered with the threshold control, the appliance is switched on for the entire defined duration.
Procedure:
•
Open the
Configuration | Special functions | Smart Home
dialog.
•
Select
Profile position
.
•
Select
Type
.
•
Activate
Profile
via the switch.
•
Select the
Switch
This switch has to be configured in the
Configuration | Devices | Smart-Home
menu.
•
Enter the typical
Nominal power
in watts.
•
Enter the profile dependent
parameters
/
•
SAVE
settings.
Generation Information on Thresholds
Five-minute values are generated to balance the fluctuations in PV production (e.g. due to clouds) for
managing appliances. The average value is aligned to the threshold set in the respective logic control.
Generation Information on typical nominal power�
The typical nominal power is the average consumption of appliances that is controlled by the profile.
Appliances, such a laundry dryer, have a short high peak of power consumption and times in which little
power is required. Based on this, it would be problematic to calculate the current power consumption for
power management control. For this reason, the Solar-Log™ calculates with the configured value for typi-
cal nominal power during the entire duration of operation.
Note
When configuring the control logic make sure to allocate profile positions so that the
power supply (for surpluses) is adjusted to the priority of the managed appliances.