beautypg.com

To select modulation source – RIGOL DG1000Z Series User Manual

Page 90

background image

RIGOL

Chapter 2 Front Panel Operations

2-40

DG1000Z User’s Guide

To Select Modulation Source

DG1000Z can accept modulating waveform from internal or external modulation
source. Press ModSource to select “Int” or “Ext” modulation source.

1. Internal Source

When internal modulation source is selected, press Shape to select Sine, Square,

Triangle, UpRamp, DnRamp, Noise or Arb as modulating waveform. The default

is Sine.
 Square: 50% duty cycle
 Triangle: 50% symmetry
 UpRamp: 100% symmetry
 DnRamp: 0% symmetry
 Arb: the arbitrary waveform selected of the current channel

Note:

noise can be used as modulating waveform but can not be used as carrier

waveform.

2. External Source

When external modulation source is selected, Shape and FM Freq will be

grayed out and disabled. The generator accepts the external modulating signal

from the [CH1/Sync/Ext Mod/Trig/FSK] connector at the rear panel. At this

time, frequency deviation of the modulated waveform is controlled by the ±5 V

signal level of the connector. For example, if the frequency deviation is set to 1

kHz, +5V signal level corresponds to a 1kHz increase of frequency and -5V signal

level corresponds to a 1kHz decrease of frequency.

[CH1/Sync/Ext Mod/Trig/FSK]

[CH2/Sync/Ext Mod/Trig/FSK]