beautypg.com

RIGOL DG1000Z Series User Manual

Page 162

background image

RIGOL

Chapter 2 Front Panel Operations

2-112

DG1000Z User’s Guide

Connect DG1000Z with PA1011:

When the connection between DG1000Z and PA1011 as shown in the figure above
succeeds, press UtilityPA Set at the front panel of DG1000Z to enter the PA
parameters setting interface.

1. Switch

Turn “On” or “Off” the external power amplifier. If “On” is selected, the PA

amplifies and then outputs the input signal (namely the output signal of the

signal generator); if “Off” is selected, the PA has no output.

2. Gain

Select “X1” or “X10” as the amplifier gain of the signal output from the PA. “X1”

means output without gain and “X10” means to amplify the signal 10 times and

then output.

3. Output

Select “Normal” or “Invert” output mode for the signal output from the PA. Pay

attention to distinguish it with Output Polarity of DG1000Z.

4. Offset

Turn “On” or “Off” the output deviation for the output from the PA. When “On” is

selected, use the numeric keyboard or direction keys and knob to set deviation

value. The available range is from -12V to 12V and the default value is 0V.

5. Store

Store the current working state of the PA in its internal memory. When the PA is

turned on the next time, it will automatically recall the stored working state.

TIP:

For specifications of PA1011, please refer to Appendix B: Specifications of

Power Amplifier.

PA1011

DG1000Z

USB Host USB Cable USB Device Output

Output BNC Cable Input