RIGOL
1-6
DG1000Z User’s Guide
3. Page Up/Down
Open the next page of the current function menu or return to the first page.
4. Return to the Previous Menu
Exit the current menu and return to the previous menu.
5. CH1 Output Connector
BNC connector with 50Ω nominal output impedance.
When Output1 is enabled (the backlight turns on), this connector outputs
waveform according to the current configuration of CH1.
6. CH2 Output Connector
BNC connector with 50Ω nominal output impedance.
When Output2 is enabled (the backlight turns on), this connector outputs
waveform according to the current configuration of CH2.
7. Channels Control Area
It is used to control the output of CH1.
—
Press this key to open the output of CH1, the backlight turns
on and the [CH1] connector outputs the waveform
according to the current configuration of CH1.
—
Press this key again to close the output of CH1 and the
backlight turns off.
It is used to control the output of CH2.
—
Press this key to open the output of CH2, the backlight turns
on and the [CH2] connector outputs the waveform
according to the current configuration of CH2.
—
Press this key again to close the output of CH2 and the
backlight turns off.
It is used to switch the current selected channel between CH1
and CH2.
CAUTION
Overvoltage protection of the output channels of CH1 and CH2 will take
effect once any of the following conditions is met. When the overvoltage
protection takes effect, the prompt message will be displayed on the
screen and the output will be disabled.
The amplitude setting in the generator is greater than 2Vpp or the
output offset is greater than |2V
DC
|, the input voltage is greater than
±11.5×(1±5%)V (<10kHz).
The amplitude setting in the generator is lower than or equal to
2Vpp or the output offset is lower than or equal to |2V
DC
|, the input
voltage is greater than ±3.5×(1±5%)V (<10kHz).