To Set Hop Frequency

Hop frequency is the modulating frequency. The range of hop frequency depends on

the carrier waveform currently selected. Press HopFreq to highlight it and input the

desired frequency value using the numeric keyboard or direction keys and knob.


 Sine: 1μHz to 60MHz
 Square: 1μHz to 25MHz
 Ramp: 1μHz to 1MHz
 Arb: 1μHz to 20MHz

To Set Modulating Polarity

Press Polarity to select the “Pos” or “Neg” polarity of the modulating waveform to

control the output frequency.

In internal modulation, set the polarity to “Pos” and the generator would output the

carrier frequency when the modulating waveform is logic low level and output the

hop frequency when the modulating waveform is logic high level. The situation is the

opposite when the polarity is set to “Neg”.

In external modulation, set the polarity to “Pos” and the generator would output the

carrier frequency when the external input signal is logic low level and output the hop

frequency when the external input signal is logic high level. The situation is the

opposite when the polarity is set to “Neg”.