beautypg.com

Eicon Networks 1530 User Manual

Page 65

background image

Web Interface Settings Glossary

65

Connection Menu > Connection Group
(when protocol is set to X.25)

Remote DTE Address

Defines the remote X.25 address the Eicon 1530 calls to establish the connection.

Range: 0-15 digits.

When the X.25 connection type is set to permanent (see the ‘Connection Type’ setting), this
parameter defines the VC number used.

Compression Type

Defines the type of compression used for X.25 traffic.

• NONE: No compression.
• EICON: Compression negotiation: CCP (Compression Control Protocol). Compression

algorithm: LZS-STAC. Check mode: LCB, Sequence number, and extended mode. Not
compatible with Cisco routers.

• BAY: Compression negotiation: WCP. Compression algorithm: Magnalink. Check mode:

LCB. Dictionary size: 8K or 32K.

• CISCO: Compression negotiation: None. Compression algorithm: LZS-STAC. Not

compatible with Eicon mode.

Connection Type

Defines the type of connection that will be established with the remote device.

• TWOWAY: Both the Eicon 1530 and remote device can initiate the connection.
• INCOMING: The remote device must initiate the connection.
• PERMANENT: A PVC is permanently established between two destinations. No call setup

is required.

Facilities

Sets the X.25 facilities used to establish an X.25 call with this profile. Encode facilities as a
hexadecimal string of characters separated by commas, colons, or hyphens. Maximum length is
14 bytes. For example: 42,07,07

User Data

Specifies the call user data the device will include when establishing an X.25 call. Encode call
user data as hexadecimal digits separated by commas, colons, or hyphens. Maximum length is
16 bytes. For example: 42,07,07

Idle Timer

Defines the maximum amount of time an X.25 connection can be idle before the connection is
dropped.

Range: 1-600 seconds. Specify 0 to disable automatic disconnection.

Default: 20 seconds.