Description

Operating Instructions for Powador 30.0-72.0 TL3_EN

Page 7

EN

3 Description

3.1

Mode of Operation

The inverter converts the DC voltage generated by the PV modules into AC voltage and feeds it into the grid. The
feed-in process begins when there is suffi

cient sunlight and a specifi c minimum voltage is present in the inverter.

If, as it gets dark, the voltage drops below the minimum voltage value, feed-in operation ends and the inverter
switches off .

3.1.1 Inverter

diagram

1

2

3

4

5
6

Figure 1: Inverter diagram

Key

1

Upper housing cover

4

Control panel

2

Doors

5

Fan cover

3

Cover for the connection area

6

Side housing cover

3.1.2 Mechanical

components

DC isolator switch

There are 3 DC isolator switches inside the inverter housing. The DC isolator switches are used to disconnect the
inverter from the PV generator in order to carry out maintenance.

Disconnecting the inverter from the PV generator

 Switch the DC isolator switches from 1 (ON) to 0

(OFF).

Connecting the inverter to the PV generator

 Switch the DC isolator switches from 0 (OFF) to 1

(ON).