Technical Data
Page 10
Operating Instructions for Powador 30.0-72.0 TL3_EN
EN
EN
4
Technical
Data
4.1
Electrical
Data
Input levels
30.0 TL3
33.0 TL3
36.0 TL3
39.0 TL3
DC MPP range from [V] to [V]*
350 ... 800
Operating range from [V] to [V]
200 ... 800
Starting voltage [V]**
250
Open circuit voltage [V]
1 000 (start to 950)
Rated current max. [A]
3 x 34.0
Max. power per tracker [W]
20,000
Number of strings
3 x 1 (M) / 3 x 4 (XL)
Number of MPP trackers
3
Polarity safeguard
Short-circuit diode
*At DC voltages below the MPP range the maximum rated current reduces the maximum input power.
**For PV generators with MPP voltages below the MPP range of the inverter: set the start voltage in the menu.
Output levels
Rated power [VA]
2,000
27,500
30,000
33,300
Grid voltage [V]
230 / 400
Rated current [A]
3 x 36.2
3 x 39.9
3 x 43.5
3 x 48.3
Rated frequency [Hz]
50/60
cos phi
0.80 inductive to 0.80 capacitive
Number of feed-in phases
3
Distortion factor [%]
< 3
General electrical data
Max. effi
ciency [%]
98.0
European effi
ciency [%]
97.8
Make current [A] / ON duration [ms]
98 / 4.4
Internal consumption: standby [W]
< 30
Internal consumption: night [W]
~1.5
Feed-in starts at [W]
120
Circuit design
IGBT, self-commutated, transformerless
Grid monitoring
Country-specifi c
CE conformity
Yes
Table 1: