background image

Configuration and Operation

Page 36

Operating Instructions for Powador 30.0-72.0 TL3_EN

EN

EN

Coun-

try-spec.

setting

menu

level

Display/

setting

Action in this menu/meaning

All countries

4

1

2

3

4

"Settings"

menu

 Open the menu: Press the right arrow button or the

OK button.

4

1

2

3

1

Language

 Select the desired language for the user interface.

4

1

2

3

1

Def. total yield

You can set the total yield to any value, for example,
when you have received a replacement unit and want to
continue the recording from the present value.

 Select the "Save" button and confi rm with the OK

button.

4

1

2

3

1

Interface

 If the inverter is a terminal unit: Activate termination

(“Bus termination” menu option)

 Assign a unique RS485 bus address to the inverter

(“RS485 address” menu item). The address must
not be the same as that of any other inverter or a
proLOG unit.

4

1

2

3

1

S0 pulse rate

 Set the pulse rate of the S0 connection.

0

1

2

3

1

Priwatt

 Open the menu: Press the right arrow button or the

OK button.

0

1

2

3

2

Activation mode

 Select operating mode

NOTE: Re-activation depends on the operating mode
selected and on the activation conditions.

0

1

2

3

2

Monitoring time

 Set time span during which the power threshold

must be exceeded without interruption.

0

1

2

3

2

Power threshold

 Set power threshold from which the monitoring

time up to activation begins.

0

1

2

3

2

Operation mode

 Power-dependent: the function remains active until

below the set power threshold.

 Time-dependent: The function is active depending

on the sunlight for the set operating time.

0

1

2

3

2

Operation time

NOTE: The menu option is only available in the
"Time-dependent" operation mode.

 After connection, the function is active for the set

operating time.

4

1

2

3

1

Quick start

 Reduce the waiting times during the self test by

pressing the “Activate” key.

4

1

2

3

1

Logging interval

 Set the time between two log data recordings.

4

1

2

3

1

Log data backup

The inverter supports the backing up of all recorded
yield data to a connected USB storage device.

 Activate or deactivate log data backup.