2 substatus data field, 1 substatus field specification, 2 extension status field specifications – Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual
Page 129: 2 substatus data field -10

7 Data Field
7.2.1 Substatus Field Specification
7-10
7.2 Substatus Data Field
7.2.1 Substatus Field Specification
The substatus field is used to monitor status of subcommands.
• Substatus Field
7.2.2 Extension Status Field Specifications
This field is used to monitor extension status.
The SMON, LTMOD_ON, and LTMOD_OFF subcommands can be used to enable monitoring.
• L_CMP_CNT (D0-D7)
This counter indicates how many times the latch sequence has been completed during continuous latch oper-
ation. It remains 0 during a normal latch operation.
• L_SEQ_NO (D8-D11)
This number indicates the number of latch sequence being completed during a continuous latch operation. It
remains 0 during a normal latch operation.
Byte
18
D7
D6
D5
D4
D3
D2
D1
D0
Reserved
Reserved
Reserved
Reserved
Reserved
SBCM-
DRDY
SBWARNG
SBALM
Bit
Name
Description
Value
Status
D0
SBALM
Subcommand alarm occurs.
0
No alarm
1
Alarm occurs
D1
SBWARNG
Subcommand warning occurs.
0
No warning
1
Warning
D2
SBCMDRDY
Subcommand Ready
(Subcommand can be received)
0
Busy
1
Ready
Byte
28
D7
D6
D5
D4
D3
D2
D1
D0
L_CMP_CNT
Byte
29
D15
D14
D13
D12
D11
D10
D9
D8
−
−
−
−
L_SEQ_NO