3) option monitor setting, 3) option monitor setting -24, 24 (3) option monitor setting – Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual
Page 113

5 Command Related Parameters
5.2.7 STATUS Field and Monitor Related Settings
5-24
(3) Option Monitor Setting
Set the contents to be monitored when Option Monitor 1 and Option Monitor 2 are selected for MONITOR 1/
2/3/4.
∗ Can only be set for Σ-V Series SERVOPACKs model SGDV-B.
Parameter
No.
Name
Remarks
Pn824
Option Monitor 1 Selection
–
0000H
Motor rotation speed [1000000H/OS]
–
0001H
Speed reference [1000000H/OS]
–
0002H
Torque (Force) [1000000H/max. torque (force)]
–
0003H
Position error (lowermost 32 bits) [reference unit]
–
0004H
Position error (uppermost 32 bits) [reference unit]
–
0005H
System reserved
–
0006H
System reserved
–
000AH Encoder count (lowermost 32 bits) [reference unit]
–
000BH
Encoder count (uppermost 32 bits) [reference unit]
–
000CH
External encoder count (lowermost 32 bits) [reference
unit]
For fully-closed loop control
000DH External encoder count (uppermost 32 bits) [reference
unit]
For fully-closed loop control
0010H
Un000: Motor rotation speed [min
-1
]
–
0011H
Un001: Speed reference [min
-1
]
–
0012H
Un002: Torque (Force) reference [%]
–
0013H
Un003: Rotation angle 1 [pulse]
–
0014H
Un004: Rotation angle 2 [degree]
–
0015H
Un005: Input signal monitor
–
0016H
Un006: Output signal monitor
–
0017H
Un007: Input position reference speed [min
-1
]
–
0018H
Un008: Position error [reference unit]
–
0019H
Un009: Accumulated load ratio [%]
–
001AH Un00A: Regenerative load ratio [%]
–
001BH
Un00B: DB resistance consumption power [%]
–
001CH
Un00C: Input reference pulse [reference unit]
–
001DH Un00D: Feedback pulse [pulse]
–
001EH
Un00E: Fully-closed loop feedback pulse [pulse]
For fully-closed loop control
0023H
Initial multiturn data [rev]
For rotational servomotors
0024H
Initial incremental pulse
For rotational servomotors
0025H
Initial absolute position data lowermost 32 bits [pulse]
For linear servomotors
0026H
Initial absolute position data uppermost 32 bits [pulse]
For linear servomotors
0027H
*
Un022: Installation environment monitor [%]
–
0080H
Previous value of latched feedback position (LPOS)
–
Others
Reserved parameters (Do not use.)
–
Pn825
Option Monitor 2 Selection (Same as for Pn824)
–