Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual
Page 126

7.1 Main Command Data Field
7-7
7
Data Field
7.1.4 Monitor Information Field Specifications: MONITOR 1/2/3/4
The monitor information (MONITOR 1/2/3/4)field is used to monitor information selected by the monitor
codes in the monitor selection field.
Applicable Commands
SV_ON, SV_OFF, HOLD, INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VELCTRL,
TRQCTRL, SMON, SENS_ON, SENS_OFF, BRK_ON, BRK_OFF, LTMOD_ON, LTMOD_OFF
The MONITOR 1/2/3/4 monitor codes are listed below.
Monitor
Code
Name
Description
Unit
0
POS
Reference position in reference coordinate system
(position after reference filtering)
Reference unit
1
MPOS
Reference position
Reference unit
2
PERR
Position error
Reference unit
3
APOS
Feedback position in machine coordinate system
Reference unit
4
LPOS
Feedback latch position in machine coordinate
system
Reference unit
5
IPOS
Reference position in reference coordinate system
(position before reference filtering)
Reference unit
6
TPOS
Target position in reference coordinate system
Reference unit
7
–
–
–
8
FSPD
Feedback speed
Position/torque (force) control: reference
units/s
Speed control: Maximum speed/
40000000H
9
CSPD
Reference speed
Position control: Reference units/s
Speed control: Maximum speed/
40000000H
A
TSPD
Target speed
Position control: Reference units/s
Speed control: Maximum speed/
40000000H
B
TRQ
Torque (force) reference (The rated torque is
100%.)
Position/speed control:
% (The rated torque is 100%.)
Torque (force) control: Maximum torque
(force)/40000000H
C
–
–
–
D
–
–
–
E
OMN1
Option monitor 1 selected in Pn824
–
F
OMN2
Option monitor 2 selected in Pn825
–