Yaskawa 120 Series I/O Modules User Manual
Page 196
4.4 Operations Using MEMOSOFT
4-49
4
(2) A screen will appear so that the software filter setting can be selected.
Move the cursor to NO FILTER, AVE 3 TIMES or AVE 5 TIMES and press the
Enter Key to select the desired software filter.
The MEMOSOFT is set by default to NO FILTER.
Fig. 4.18 Software Filter Selection
The software filter selection is only for Analog Input Modules, but not for Analog
Output Modules.
7) Setting the Timeout Output (Only for Analog Output Modules)
Make sure that the Parameter Setting Screen (I/O Map Module Editor) is being dis-
played.
(1) Move the cursor to OUT STATUS WHEN CPU STOP and press the Enter Key
to access the timeout output setting.
Fig. 4.19 Parameter Setting Screen: Timeout Output
(2) A screen will appear so that the timeout output setting can be selected.
Move the cursor to OPEN OUTPUT, HOLD OUTPUT or SET BY USER and
press the Enter Key to select the desired timeout output status. If HOLD OUT-
PUT is selected, the data just before the CPU Module entered STOP status will
be sent for all outputs until the CPU Module returns to RUN status.
INFO
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)