beautypg.com

SMA SSM16-11 User Manual

Page 79

background image

SMA Solar Technology AG

13  Technical Data

Installation Guide

SSM16-24-IA-IEN105120

79

DC String Connection to MC4 Plug Connector

DC String Connection to MC3 Plug Connector

DC String Connection to Plug Connector SUNCLIX

DC String Connection to Spring-Type Terminal

DC String Connection to Disconnection and Measuring Terminal

Grounding Connection

Cable cross section

6 mm

2

Maximum rated current

30 A

Cable cross section

4 mm

2

Maximum rated current

20 A

Cable type

PV1-F

Cable cross section

2.5 mm

2

… 6 mm

2

Cable diameter

5 mm … 8 mm

Maximum rated current

40 A

Grip range

0.2 mm

2

… 6 mm

2

Cable gland

M32

Cable support sleeve

3 x 5 mm / 3 x 7 mm / 3 x 9 mm

Type of terminal

Spring terminal

Maximum connection cross section

0.2 mm

2

… 6 mm

2

Cable entry via multiple cable gland

M50

Grip range of multiple cable gland

5.0 mm … 5.5 mm / 5.6 mm … 6.0 mm /
6.1 mm … 7.0 mm / 7.1 mm … 8.0 mm /

8.1 mm … 9.0 mm

Type of terminal

Cage clamp

Maximum connection cross section

35 mm

2

Cable entry via cable gland

M25

Cable gland clamping zone

7 mm … 14 mm