SMA SSM16-11 User Manual
Page 79

SMA Solar Technology AG
13 Technical Data
Installation Guide
SSM16-24-IA-IEN105120
79
DC String Connection to MC4 Plug Connector
DC String Connection to MC3 Plug Connector
DC String Connection to Plug Connector SUNCLIX
DC String Connection to Spring-Type Terminal
DC String Connection to Disconnection and Measuring Terminal
Grounding Connection
Cable cross section
6 mm
2
Maximum rated current
30 A
Cable cross section
4 mm
2
Maximum rated current
20 A
Cable type
PV1-F
Cable cross section
2.5 mm
2
… 6 mm
2
Cable diameter
5 mm … 8 mm
Maximum rated current
40 A
Grip range
0.2 mm
2
… 6 mm
2
Cable gland
M32
Cable support sleeve
3 x 5 mm / 3 x 7 mm / 3 x 9 mm
Type of terminal
Spring terminal
Maximum connection cross section
0.2 mm
2
… 6 mm
2
Cable entry via multiple cable gland
M50
Grip range of multiple cable gland
5.0 mm … 5.5 mm / 5.6 mm … 6.0 mm /
6.1 mm … 7.0 mm / 7.1 mm … 8.0 mm /
8.1 mm … 9.0 mm
Type of terminal
Cage clamp
Maximum connection cross section
35 mm
2
Cable entry via cable gland
M25
Cable gland clamping zone
7 mm … 14 mm