SMA SSM16-11 User Manual
Page 33
SMA Solar Technology AG
6 Electrical Connection
Installation Guide
SSM16-24-IA-IEN105120
33
✖ Is the stranded wire not visible in the chamber?
The stranded wire is not correctly in place.
• Declamp the clamping clip. To do this insert
a screwdriver with a 3.5 mm blade into the
clamping clip and pry it out.
• Remove the wire and start again from step 2.
4. Push the bolted connection toward the thread and
screw it tight (torque of 2 Nm).
Connect the SUNCLIX DC plug connectors to the Sunny String-Monitor
1. Remove the transport plugs from all the DC plug connectors.
2. Connect the assembled DC connectors to the Sunny String-Monitor.
☑ The DC connectors click audibly into position.
3. Ensure that all DC connectors are securely in place.
4. Insert the sealing plugs into the DC connectors that
are not required. This way you seal the DC plug
connectors.
Sealing plug
The sealing plugs included in the delivery are meant only for the DC plug connectors.
• Do not insert the sealing plugs into the DC inputs on the Sunny String-Monitor.
+
1
2
+
1
2