6  Electrical Connection

Installation Guide

SSM16-24-IA-IEN105120

33

✖ Is the stranded wire not visible in the chamber?

The stranded wire is not correctly in place.
• Declamp the clamping clip. To do this insert

a screwdriver with a 3.5 mm blade into the
clamping clip and pry it out.

• Remove the wire and start again from step 2.

4. Push the bolted connection toward the thread and

screw it tight (torque of 2 Nm).

Connect the SUNCLIX DC plug connectors to the Sunny String-Monitor

1. Remove the transport plugs from all the DC plug connectors.
2. Connect the assembled DC connectors to the Sunny String-Monitor.

☑ The DC connectors click audibly into position.

3. Ensure that all DC connectors are securely in place.
4. Insert the sealing plugs into the DC connectors that

are not required. This way you seal the DC plug
connectors.

Sealing plug

The sealing plugs included in the delivery are meant only for the DC plug connectors.

• Do not insert the sealing plugs into the DC inputs on the Sunny String-Monitor.

+

1

2

+

1

2

This manual is related to the following products: