Comparison: Specifications

Function

TNC 320

iTNC 530

Axes

6 maximum

18 maximum

Input resolution and display step

:

Linear axes

0.1µm

0.1 µm

Rotary axes

0.001°

0.0001°

Display

15.1-inch TFT color

flat-panel display

19-inch TFT color

flat-panel display or

15.1-inch TFT color

flat-panel display

Memory media for NC, PLC programs and system files

CompactFlash

memory card

Hard disk or SSDR

solid state disk

Program memory for NC programs

2 GB

> 21 GB

Block processing time

6 ms

0.5 ms

HeROS operating system

yes

yes

Windows XP operating system

no

Option

Interpolation:

Straight line
Circle
Helix
Spline

5 axes
3 axes
yes
no

5 axes
3 axes
yes
Yes with option 9

Hardware

Compact in

operating panel

Modular in

electrical cabinet

Comparison: Data interfaces

Function

TNC 320

iTNC 530

Gigabit Ethernet 1000BaseT

X

X

RS-232-C/V.24 serial interface

X

X

RS-422/V.11 serial interface

-

X

USB interface

X

X