beautypg.com

Displaying a basic rotation, Canceling a basic rotation – HEIDENHAIN TNC 320 (77185x-01) User Manual

Page 445

background image

Compensating workpiece misalignment with 3-D touch probe

13.7

13

TNC 320 | User's Manual

HEIDENHAIN Conversational Programming | 3/2014

445

Displaying a basic rotation

When you select the

PROBING ROT function, the TNC displays

the active angle of basic rotation in the dialog

Rotation angle. The

TNC also displays the rotation angle in the additional status display
(

STATUS POS.).

In the status display a symbol is shown for a basic rotation

whenever the TNC is moving the axes according to a basic rotation.

Canceling a basic rotation

Select the probe function by pressing the

PROBING ROT soft

key
Enter a rotation angle of zero and confirm with the

SET BASIC

ROTATION soft key
Terminate the probe function by pressing the END soft key