beautypg.com

Identifying basic rotation, Saving a basic rotation in the preset table, Ation ("compensation of – HEIDENHAIN TNC 320 (77185x-01) User Manual

Page 444

background image

Manual operation and setup

13.7 Compensating workpiece misalignment with 3-D touch probe

13

444

TNC 320 | User's Manual

HEIDENHAIN Conversational Programming | 3/2014

Identifying basic rotation

Select the probe function by pressing the

PROBING ROT soft key
Position the touch probe at a position near the first

touch point
Select a probe direction perpendicular to the angle

reference axis: Select the axis and direction using

an arrow key
Start the probing procedure: Press the machine

START button
Position the touch probe at a position near the

second touch point
To probe the workpiece, press the machine START

button. The TNC determines the basic rotation and
displays the angle after the dialog

Rotation angle

Activate basic rotation: Press the

Set basic

rotation soft key
Terminate the probe function by pressing the END

soft key

Saving a basic rotation in the preset table

After the probing process, enter the preset number in which the
TNC is to save the active basic rotation in the

Number in table:

input box
Press the

BASIC ROT. IN presettab. soft key to save the basic

rotation in the preset table

Compensation of workpiece misalignment by rotating
the table

To compensate the identified misalignment by a rotary table
position, press the

ALIGN ROTARY TABLE soft key after the

probing process

Position all axes to avoid a collision before table

rotation. The TNC outputs an additional warning

before table rotation.

If you want to set the datum in the rotary table axis, press the

SET TABLE ROTATION soft key.
You can also save the misalignment of the rotary table in any

line of the Preset table. Enter the line number and press the

TABLEROT IN PRESETTAB. soft key. The TNC saves the angle

in the offset column of the rotary table, e.g. in the C_OFFS

column with a C axis. If necessary, the view in the Preset table
has to be changed with the

BASIS-TRANSFORM./OFFSET soft

key to display this column.