beautypg.com

HEIDENHAIN TNC 320 (77185x-01) User Manual

Page 436

background image

Manual operation and setup

13.5 Using 3-D touch probes

13

436

TNC 320 | User's Manual

HEIDENHAIN Conversational Programming | 3/2014

Writing measured values from the touch probe cycles
in a datum table

Use this function if you want to save measured

values in the workpiece coordinate system. If you

want to save measured values in the machine-based

coordinate system (REF coordinates), press the

ENTER IN PRESET TABLE soft key, see "Writing

measured values from the touch probe cycles in the

preset table", page 437.

With the

ENTER IN DATUM TABLE soft key, the TNC can write the

values measured during a touch probe cycle in a datum table:

Select any probe function
Enter the desired coordinates of the datum in the appropriate

input boxes (depends on the touch probe cycle being run)
Enter the datum number in the

Number in table= input box

Press the

ENTER IN DATUM TABLE soft key. The TNC saves the

datum in the indicated datum table under the entered number