Checking and changing Q parameters

9.7

9

TNC 320 | User's Manual

HEIDENHAIN Conversational Programming | 3/2014

279

You can have the Q parameters be shown in the additional status

display in the Manual, El. Handwheel, Single Block, Full Sequence

and Test Run operating modes.

If you are in a program run, interrupt it if required (for example,
by pressing the machine STOP button and the

INTERNAL STOP

soft key). If you are in a test run, interrupt it.

Call the soft-key row for screen layout

Select the layout option for the additional status

display: In the right half of the screen, the TNC
shows the

Overview status form

Press the

STATUS OF Q PARAM. soft key

Press the

Q PARAMETER LIST soft key

The TNC opens a pop-up window in which you

can enter the desired range for display of the

Q parameters or string parameters. Multiple Q

parameters are entered separated by commas

(e.g. Q 1,2,3,4). To define display ranges, enter a

hyphen (e.g. Q 10-14).