beautypg.com

Machine-specific user parameters 17.1 – HEIDENHAIN TNC 320 (77185x-01) User Manual

Page 531

background image

Machine-specific user parameters 17.1

17

TNC 320 | User's Manual

HEIDENHAIN Conversational Programming | 3/2014

531

Parameter settings

DisplaySettings

Behavior during control startup

Acknowledge the "Power interrupted" message

TRUE: Run-up is continued only after the message has been acknowledged
FALSE: The "power interrupted" message does not appear

Depiction of the cycles

TNC_STD: Display the cycles with comments
TNC_PARAM: Display the cycles without comments

DisplaySettings

Settings for program-run graphics

Type of graphic display

High (compute-intensive): The orientation of linear and rotary axes is considered for the
graphic display (3-D)
Low: Only the orientation of linear axes is considered for the program-run graphics (2.5-
D).
Disabled: The program-run graphics are deactivated

ProbeSettings

Configuration of probing behavior

Manual operation: Inclusion of basic rotation

TRUE: Including active basic rotation during probing
FALSE: Always move on paraxial path during probing

Automatic mode: Multiple measurements in probing functions

1 to 3 Probe points per probing process

Automatic mode: Confidence range for multiple measurement

0.002 to 0.999 [mm]: Range within which the measured value must be during multiple
measurements

Configuration of a round stylus

Coordinates of the stylus center

[0]: X coordinate of the stylus center with respect to the machine datum
[1]: Y coordinate of the stylus center with respect to the machine datum
[2]: Z coordinate of the stylus center with respect to the machine datum

Safety clearance above the stylus for pre-positioning

0.001 to 99 999.9999 [mm]: Safety clearance in tool axis direction

Safety zone around the stylus for prepositioning

0.001 to 99 999.9999 [mm]: Safety clearance in the plane perpendicular to the tool axis