Calibrating a 3-D touch trigger probe

13.6

13

TNC 320 | User's Manual

HEIDENHAIN Conversational Programming | 3/2014

439

Calibrating the effective length

HEIDENHAIN only gives warranty for the function of

the probing cycles if HEIDENHAIN touch probes are

used.

The effective length of the touch probe is always

referenced to the tool datum. The machine tool

builder usually defines the spindle tip as the tool

datum.

Set the datum in the spindle axis such that for the machine tool

table Z=0.

Select the calibration function for the touch probe
length: Press the

CAL. L soft key. The TNC opens

a menu window with input fields
Datum for length: Enter the height of the ring

gauge
New cal. spindle angle: Spindle angle that is used

for the calibration. The TNC uses CAL_ANG from

the touch probe table as a default value. If you

change the value, the TNC saves the value to the

touch probe table during calibration
Move the touch probe to a position just above the

ring gauge
To change the traverse direction (if necessary),

press a soft key or an arrow key
To probe the upper surface of the ring gauge,

press the machine START button
Check the results (change the values if required)
Press the

OK soft key for the values to take effect

Press the

END soft key to terminate the calibrating

function