Press the
Configuration button to open the Configuration
menu:
Setting
Meaning
Status
Active interface: Connection status of
the selected Ethernet interface
Name: Name of the interface you are
currently configuring
Plug connection: Number of the plug
connection of this interface on the logic
unit of the control
Profile
Here you can create or select a profile in
which all settings shown in this window are
stored. HEIDENHAIN provides two standard
profiles:
DHCP-LAN: Settings for the standard
TNC Ethernet interface, should work in a
standard company network
MachineNet: Settings for the second,
optional Ethernet interface; for
configuration of the machine network
Press the corresponding buttons to save,
load and delete profiles
IP address
Option
Automatically procure IP
address: The TNC is to procure the IP
address from the DHCP server
Option
Manually set IP address: Manually
define the IP address and subnet mask.
Input: Four numerical values separated by
points, in each field, e.g.
160.1.180.20
and
255.255.0.0
Domain Name
Server (DNS)
Option
Automatically procure DNS: The
TNC is to automatically procure the IP
address of the domain name server
Option
Manually configure DNS: Manually
enter the IP addresses of the servers and
the domain name
Default
gateway
Option
Automatically procure default
GW: The TNC is to automatically procure
the default gateway
Option
Manually configure default GW:
Manually enter the IP addresses of the
default gateway
Apply the changes with the
OK button, or discard them with the