Technical specifications, Ac power requirements, Power cables – Grass Valley PRS 250 RAID Storage System User Manual
Page 81: Operating limits, Nonoperating limits (shipping and storing), Appendix a, Appendix

RAID Instructions
A-1
Appendix
A
Technical Specifications
This appendix lists the technical specifications for the PRS200 and PRS200A RAID
Storage chassis.
AC power requirements
Voltage
90 V ac to 264 V ac, single-phase,
47 Hz to 63 Hz; power supplies are
auto-sensing and auto-ranging
Current draw
9.0 A max. at 100 V ac input
Power consumption
Apparent power
900 VA max
True power
880 W max
Phase
1 inside USA; 2 or 3 outside USA
Power cables
USA primary power
1.8 m (6.0 ft.): NEMA L5-15P connection,
L5-15R mating connection
Other locations
Local standard ac connection
Operating limits
Ambient temperature
10
°
C to 38
°
C (50
°
F to 100
°
F)
Relative humidity
20 to 80% non-condensing
Elevation
2439 m (8000 ft.)
Heat dissipation
3168x10
3
J/hr (3000 Btu/hr.) max
Shock
3 g @ 11ms
Vibration
0.25 g peak @ 5 Hz to 500 Hz
Non-operating limits (shipping and storing)
Ambient temperature
-40
°
C to 65
°
C (-40
°
F to 149
°
F)
Gradient, maximum
24
°
C/hr (43.2
°
F/hr)
Relative humidity
10% to 90% non-condensing
Elevation
7625 m (25,000 ft.)