Technical Specifications

This appendix lists the technical specifications for the PRS200 and PRS200A RAID
Storage chassis.

AC power requirements

Voltage

90 V ac to 264 V ac, single-phase,
47 Hz to 63 Hz; power supplies are
auto-sensing and auto-ranging

Current draw

9.0 A max. at 100 V ac input

Power consumption

Apparent power

900 VA max

True power

880 W max

Phase

1 inside USA; 2 or 3 outside USA

Power cables

USA primary power

1.8 m (6.0 ft.): NEMA L5-15P connection,
L5-15R mating connection

Other locations

Local standard ac connection

Operating limits

Ambient temperature

10

°

C to 38

°

C (50

°

F to 100

°

F)

Relative humidity

20 to 80% non-condensing

Elevation

2439 m (8000 ft.)

Heat dissipation

3168x10

3

J/hr (3000 Btu/hr.) max

Shock

3 g @ 11ms

Vibration

0.25 g peak @ 5 Hz to 500 Hz

Non-operating limits (shipping and storing)

Ambient temperature

-40

°

C to 65

°

C (-40

°

F to 149

°

F)

Gradient, maximum

24

°

C/hr (43.2

°

F/hr)

Relative humidity

10% to 90% non-condensing

Elevation

7625 m (25,000 ft.)